Product Preparation & Application
Material Preparation:
Catalyze Ultra Solids White Conversion Coating with pre-packaged catalyst kit in a stainless steel or plastic lined container. Mix or agitate thoroughly and allow a 20 minute induction period prior to application. This material is prepared at application viscosity and should require no thinning prior to use. However, if the conditions at your facility dictate that a thinner be incorporated, we recommend the use of our SOL-9011 HAPs Free Thinner or SOL-9013 Non HAPS/Non VOC Thinner at levels not to exceed 10% by volume. If a slower dry time is required, use SOL9012, HAPS Free Retarder at a level not to exceed 4% by volume.
Application:
Because of the short dry time, this product must be applied with professional spray equipment. This product is used as a self-sealing system. When used as a self-sealing system we recommend no more than three coats and not to exceed 3 mils wet film build per coat. When used in conjunction with our precatalyzed vinyl primer, 110-0002, we recommend one coat of precatalyzed vinyl primer not to exceed 3 mils wet film build and no more than two coats of Ultra Solids White Conversion Coatings not to exceed 3 mils wet film build per coat. Total dry film build of the complete coating system is not to exceed 3 mils.
Clean-up:
Use #500 Gem Coat Lacquer Thinner or SOL-9011 HAPs Free Lacquer Thinner to clean all equipment. Dispose of in accordance with Federal, State, and Local regulation regarding pollution.